Brand Name :SYSEYE
Model Number :ST-1000
Certification :TUV
Place of Origin :China
MOQ :1
Price :$6,500.00-$7,900.00
Payment Terms :T/T
Supply Ability :100
Delivery Time :5 working days
Packaging Details :380 mm (L) x 460mm (W) x 505mm (H)
Product name :Full-Auto Non Contact Tonometer
CPU :i3 and above
Memory :4GB
Hard disk :120G or above
Working distance :≥11mm
R/L :automatic detection and display
Recording :build-in printer
feature :Full-Auto Non Contact
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Non Contact Tonometer Automatic green LED for clinical diagnosis of ophthalmology

Non-contact tonometer (NCT) has been gradually recognized and accepted by more and more patients because of its advantages such as simple operation, rapid measurement, automatic printing of test results, no direct contact with the eyeball, no superficial anesthesia, and no pain for patients.

St-1000p is a non-contact tonometer with automatic alignment. The test of intraocular pressure is an important index for clinical diagnosis of ophthalmology. Our st-1000p non-contact tonometer adopts non-contact measurement with no risk of infection, simple operation and easy acceptance by patients.

St-1000p adopts Imber-Fick principle and USES controllable air pulse with linear increasing characteristics to squeeze the central position of the cornea and deform the cornea to form a circular plane with a diameter of about 3.6mm2. It is considered that the air pressure at this time is equal to the pressure inside the eyeball, and the measured air pressure at this time is the value of the intraocular pressure directly.

Non Contact Tonometer specification

Intraocular pressure (IOP) measuring range 1mmHg~ 30mmHg /1mmHg ~60mmHg ( precision of 1mmHg)
Measuring system dual sensor system of light and pressure
Working distance ≥11mm
R/L automatic detection and display
Measuring result 10 times per eye; 3 times result printing per eye
Recording build-in printer
Measuring mode auto/manual
Movement range ≥30mm(front to back)/ 90mm(left to right)/ 30mm(vertical)
Jaw layer vertical movement ≥30mm(front to back)/ 90mm(left to right)/ 30mm(vertical)
Display mode 10.1-inch HDMI color LED touch monitor
Output port USB2.0

Product Description Of Non Contact Tonometer

Screen color and touch,

Rotating screen like Topcon.

Motorized chinrest

Auto tracking eye , you can select auto or manual .

if select auto , will automatic adjust the chinrest distance , height, and shoot air to measure . two second finish .

2.3.1 measurement range: 1mmHg~60mmHg

2.3.2 measuring range: 30mmHg, 60mmHg

2.3.3 measurement accuracy: 1mmHg (intraocular pressure)

2.3.4 focusing mode: auto focusing/manual focusing

2.3.5 internal fixation: green LED

2.3.6 nozzle stroke: up and down: 30mm; Front and rear: 35mm; Left and right: 90mm.

2.3.7 jaw rest stroke: 60mm

Intraocular pressure (IOP) measuring range: 1mmHg~ 30mmHg /1mmHg ~60mmHg ( precision of 1mmHg)
Measuring system: dual sensor system of light and pressure
Working distance:≥11mm
R/L: automatic detection and display
Measuring result: 10 times per eye; 3 times result printing per eye
Recording: build-in printer
Measuring mode: auto/manual
Focus: when luminous spot is in the focus frame, 2 modes can be chosen.
Auto mode: auto intraocular pressure measurement
Manual mode: when it's good focus, the frame will turn yellow into green, and click to start the measurement
Error indication: if the measurement signal is weak, the IOP will be enclosed by ( ), or display “ERR ”
Safety limit button: install measurement for minimum distance between head and patient
Safety functions: the distance between air nozzle and cornea is controlled in preset range(such as 11mm); it will stop going forward when the cornea is too closed to air head.
Movement range:≥30mm(front to back)/ 90mm(left to right)/ 30mm(vertical)
Jaw layer vertical movement: 0~65mm with under jaw layer
Display mode: 10.1-inch HDMI color LED touch monitor
Output port: USB2.0
Working platform: electric elevating platform


Automatic Non Contact Tonometer Green LED 120G Of OphthalmologyAutomatic Non Contact Tonometer Green LED 120G Of Ophthalmology

Company Introduction

Automatic Non Contact Tonometer Green LED 120G Of Ophthalmology

Focusing on the two major public health problems of adolescent myopia and elderly ophthalmology, our company researches new diagnostic and treatment equipment for ophthalmology, develops low-cost applicable technology products, realizes industrialization, reduces the cost of social medical and health system, and serves the strategic needs of national health.The company always adhere to the "high-tech,new vision" for the enterprise development concept.We have a strong technical force, has been awarded 11 patents, and obtained 13,485 quality system certification.Bio has established an efficient marketing team and a perfect after-sales service system to provide medical equipment with the highest cost performance and meticulous service.

Automatic Non Contact Tonometer Green LED 120G Of Ophthalmology

Inquiry Cart 0