Chongqing Bio Newvision Medical Equipment Ltd.

Build Ophthalmic Equipment Flag Exploit Dignosis New Era

Manufacturer from China
Verified Supplier
4 Years
Home / Products / Optical Coherence Tomography Machine /

SD Optical Coherence Tomography Machine Noninvasive Ophthalmic Imaging Diagnostic Techniques

Contact Now
Chongqing Bio Newvision Medical Equipment Ltd.
Visit Website
City:chongqing
Province/State:chongqing
Country/Region:china
Contact Person:MrRobert Wang
Contact Now

SD Optical Coherence Tomography Machine Noninvasive Ophthalmic Imaging Diagnostic Techniques

Ask Latest Price
Video Channel
Brand Name :SYSEYE
Model Number :RetiView 500
Certification :TUV
Place of Origin :China
MOQ :1
Price :$18,500.00-$21,900.00
Payment Terms :T/T
Supply Ability :100
Delivery Time :5 working days
Packaging Details :497 mm × 395 mm × 490 mm (L × W × H) 34 kg (75 lbs)
product name :Noninvasive Ophthalmic Imaging Diagnostic Techniques Optical Coherence Tomography Machine
Dimensions Weight :34 kg (75 lbs)
Axial resolution :≤6 µm (in tissue)
Transverse resolution :≤20 µm (in tissue)
Scan depth :≥2.5 mm (in air)
Focus adjustment :-15D to +15D
Pupil diameter :≥3 mm
feature :Noninvasive Ophthalmic Imaging Diagnostic Techniques
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Noninvasive Ophthalmic Imaging Diagnostic Techniques Optical Coherence Tomography Machine

Optical Coherence Tomography Machine images showed that fluid from the retinal detachment or cleavage cavity had channels leading behind the optic nerve and had no communication with the vitreous body. Optical Coherence Tomography Machine helps us to reunderstand the nature of the disease, but OCT clearly shows that the macular neurocortex has thinned and almost disappeared. If pathological myopia does not have crack again of extremely shallow break off or be amalamative retinal split, retinal split can be seen at congenital and a variety of diseases such as inflammation, trauma, denaturation, be in pathological myopia nevertheless more see. These lesions are not visible by other imaging methods, and OCT allows us to redefine the associated fundus lesions.

Compact Design

Features:

1. Compact Design: Everything is inside this compact body. No external computer is needed. Plug in the power cable, then you are ready to go.
2. PC Inside: Data acquisition and processing are accomplished by the internal computer. The data can be transported via ethernet or external harddrive. Peripheral devices, such as keyboard or printer, can be connected to the computer ports.
3. Easy Installation:No complex connection or setup. Compact body can fit in even small space.

Specifications of Optical Coherence Tomography Machine

Methodology Spectral domain OCT
Axial resolution ≤6 µm (in tissue)
Transverse resolution ≤20 µm (in tissue)
Scan depth ≥2.5 mm (in air)
Scan range ≥6 mm
Scan speed ≥24,000 A-scans/sec, up to 36,000 A-scans/sec
Scan modes 3D, Raster, Circle
Fundus image OCT en face
Focus adjustment -15D to +15D
Pupil diameter ≥3mm
OCT light source 840 nm SLD
Optical power 750 µW (at cornea)
Operation 13.3” touch screen, optional external mouse or keyboard
Power supply 100-240 V, 50/60 Hz
Dimensions Weight 34 kg (75 lbs)

Optical Coherence Tomography Machine has never been so affordable. More people can benefit from the advanced technology now.

Step 1
Choose left or right eye. Push the direction buttons to move the target eye to the center of the field of view, then start data acquisition.
Step 2
Enter the data acquisition interface. The device is able to search for the OCT signal and optimize it automatically.
Step 3

Browse and analyze the acquired images.

SD Optical Coherence Tomography Machine Noninvasive Ophthalmic Imaging Diagnostic Techniques

SD Optical Coherence Tomography Machine Noninvasive Ophthalmic Imaging Diagnostic Techniques

SD Optical Coherence Tomography Machine Noninvasive Ophthalmic Imaging Diagnostic Techniques

SD Optical Coherence Tomography Machine Noninvasive Ophthalmic Imaging Diagnostic Techniques

SD Optical Coherence Tomography Machine Noninvasive Ophthalmic Imaging Diagnostic Techniques

Company Introduction

SD Optical Coherence Tomography Machine Noninvasive Ophthalmic Imaging Diagnostic Techniques

Focusing on the two major public health problems of adolescent myopia and elderly ophthalmology, our company researches new diagnostic and treatment equipment for ophthalmology, develops low-cost applicable technology products, realizes industrialization, reduces the cost of social medical and health system, and serves the strategic needs of national health.The company always adhere to the "high-tech,new vision" for the enterprise development concept.We have a strong technical force, has been awarded 11 patents, and obtained 13,485 quality system certification.Bio has established an efficient marketing team and a perfect after-sales service system to provide medical equipment with the highest cost performance and meticulous service.

SD Optical Coherence Tomography Machine Noninvasive Ophthalmic Imaging Diagnostic Techniques

Inquiry Cart 0